The Geotechnical Report: What the Soil Tells You Before You Build a Hill Country Custom Home

Before an architect draws the first line of a house on your land, the ground has to be asked what it will carry. On a lot in West Lake Hills, on Lake Austin or in central Austin, the answer belongs to that lot alone. The geotechnical report is the document that records it, and it comes before the foundation design, not after. Here is when to order one, what is in it, and how to read it.
Quick answer: a geotechnical report is a geotechnical engineer’s written investigation of the soil and rock under a building site, usually built from borings and lab tests and ending in foundation recommendations. The building code leaves the soil test to the local building official where soil conditions are questionable, but the Texas Section of ASCE recommends one before any foundation design, and we do not start design without it. Order it before you close on the land if your contract allows, and expect it to read very differently on a Hill Country lot than on a Blackland one.
Why the Geotechnical Report Comes Before the Foundation Design
A foundation is designed against known ground conditions, and the report is where they become known. The Texas Section of the American Society of Civil Engineers puts the order plainly in its 2007 recommended practice for residential foundations: “Prior to foundation design, a geotechnical investigation and report shall be completed by a geotechnical engineer.” It is a recommended practice, not law.
The model International Residential Code (IRC) leaves the soil test to the building official when soil science points to expansive, compressible or shifting soils (section R401.4). Texas licensing law adds a condition. Texas Occupations Code Section 1001.056 exempts people who draw plans for a private dwelling from engineering licensing, under conditions, but subsection (c)(2) says the exemption does not apply to engineering design of a residential slab on expansive soil that meets the IRC’s classification, unless the work meets the IRC as applied in the jurisdiction. It governs who may design the slab, not whether a report is ordered.
None of these makes a geotechnical report mandatory on every custom home. We require one anyway. Our structural engineers see the soil report before a single line is drawn, as our guide to site-specific design describes, so the foundation is designed for the lot rather than adjusted on site.
Two Soil Worlds on Either Side of the Escarpment
The Bureau of Economic Geology at UT Austin says the escarpment generally parallels MoPac in Austin. West of MoPac the city becomes hilly, and east of it, relatively flat. BEG’s Mount Bonnell sign adds that the break defines major differences in soils, with the Blackland Prairies to the east and the Hill Country and Edwards Plateau to the west. West Lake Hills sits in the Hill Country. Pflugerville sits on the Blackland side.
That is why the report reads differently in each place. USDA describes the Houston Black clay series as very deep, 40 to 60 percent clay, with cracks 0.5 to 4 inches wide when dry that run 12 inches or more down. The Eckrant, Brackett and Speck series, mapped around West Lake Hills, put limestone bedrock at roughly 4 to 20 inches. USDA mapping around Pflugerville shows mostly Houston Black and other clay or chalk-derived soils. Around West Lake Hills it shows mostly shallow soil over limestone, with some deeper Volente soil mixed in.

| East of the escarpment | West of the escarpment | |
|---|---|---|
| Landscape (BEG) | Relatively flat | Hilly |
| Typical soil (USDA) | Houston Black clay, very deep | Eckrant, Brackett, Speck: shallow soil over limestone |
| Depth to rock (series descriptions) | Very deep soil; no rock depth given | About 4 to 20 inches in the series descriptions; your lot may differ |
| What the report watches | How much the clay swells and shrinks | Where the rock is and how fractured it is |
| Exceptions nearby | Chalk-derived soils (USDA's Austin series) | Deeper Volente soil |
Read the table as tendencies. “Clay east, rock west” fails on both sides. Look up your lot in USDA’s Web Soil Survey, then have it investigated.
What the Investigation Does: Borings, Lab Tests and Two Numbers
The investigation starts with borings: holes drilled where the house is likely to sit, with samples tested in a lab. ASCE’s recommended practice says one boring may be enough for a single lot with a simple residence under 2,500 square feet. It says more may be needed on sites with fill, large footprints or varying geology such as steep slopes or nearby fault zones. Borings should reach at least 20 feet unless confirmed rock is found sooner (shallower for some granular soils), and a site that is obviously rock can be investigated with shallow test pits. Those are recommended-practice figures, not Austin code.
Lab work may include moisture content, Atterberg limits, swell and shrinkage tests, soil suction and consolidation. Two terms you will likely see.
The plasticity index (PI) comes from the Atterberg limits and measures the range of moisture over which the soil stays plastic. The IRC lists a PI of 15 or greater as one of four criteria for expansive soil. Potential vertical rise (PVR) estimates how far the soil could swell when exposed to water, at a given density, moisture and load. TxDOT’s Tex-124-E procedure applies it to the soil below a building foundation and expresses it in inches.
A complete geotechnical report also carries the boring logs and a plan of where each boring sits, the lab results, a site description (topography, trees, seeps, faults, groundwater, fill), the foundation recommendations and the engineer’s seal. When the report arrives, ask the engineer four questions. Do the borings cover the whole footprint? How deep is rock, and how consistent is that depth from boring to boring? What do the PI and PVR say the soil could do? What drainage and moisture conditions does the recommendation assume?
How the Engineer Turns the Report Into a Foundation
The foundation engineer reads the geotechnical report and selects a system. ASCE says the foundation design engineer is the engineer of record, and that the geotechnical and foundation work “may be performed by the same individual.” The report can point toward a slab on engineered select fill, a post-tensioned slab, drilled piers to rock, or a pier-and-beam or structural slab above a void.
Each option asks the report for different data. For post-tensioned slabs, ASCE has the report supply edge-lift and center-lift parameters.
Our construction timeline guide says foundation type is engineered against the soil report. For the decision itself, see how the report shapes the pier-and-beam versus slab choice.
Engineering matters at the end, too. A City of Austin Building Criteria Manual rule adopted in 2015 says city inspectors will not perform foundation inspections for new construction. Instead, a registered design professional verifies the foundation was built to the adopted code or an engineered design, with the report delivered at the final inspection. Confirm the current requirement with Development Services.
Shallow Rock: What It Changes and How Removal Is Regulated
Shallow rock changes the work, and the report is where it becomes a number for your lot. Our pier-and-beam guide calls pier depth one of the larger swing variables in foundation cost, and where piers bear on rock, the depth to rock in the report is one of the findings the engineer works from. Rock does not swell and shrink like clay, but USDA’s Brackett description calls the bedrock weakly cemented, fractured and weathered limestone with vertical fractures, so rock brings design questions of its own.
Removal rules are local. West Lake Hills’ code says the purpose of its Article 12.05, adopted in 2018, “is to prohibit blasting and the use of explosives in the city limits.” Other provisions of the city’s code still describe blasting permits, so confirm with the city how they apply before planning rock removal there. Our guide to building in West Lake Hills explains that West Lake Hills, not the City of Austin, decides under its own Code of Ordinances. Austin adopted the 2024 fire code with local amendments, so confirm blasting permit requirements with the Austin Fire Department before planning on it.
Drainage and Grading Around the House
A report’s recommendations often assume the water around the house is managed. IRC section R401.3 says lots shall be graded to drain surface water away from foundation walls, with the grade falling not fewer than 6 inches within the first 10 feet. Where lot lines, walls or slopes prevent that, drains or swales must carry water away, and impervious surfaces within 10 feet of the foundation must slope at least 2 percent away from the building. Austin adopted the 2024 edition with local amendments, so confirm which edition your city uses. On a lot in the Lake Travis watershed, LCRA’s Highland Lakes Watershed Ordinance may also apply to grading and erosion control. A 2001 Foundation Performance Association practice, written for Houston, also says a good report discusses the maintenance needed to keep the design working.
When to Order It, Who Pays and How Long It Takes
If you are buying, order the geotechnical report before closing if the contract allows. Where the sale uses TREC’s Unimproved Property Contract, paragraph 5B lets the buyer, for an option fee, terminate by notice within an option period whose length the parties fill in, and paragraph 7A requires the seller to allow the buyer access at reasonable times. The form does not mention soil reports, so access for a drilling rig and enough days are matters to negotiate. Ask your agent for an option period long enough to schedule borings and receive the sealed report.
The survey and the soil report work as a pair. Our companion piece on easements, setbacks and the survey covers where the house can sit, and the report covers what will hold it up. Our guide to buying a lot in The Reserve at Lake Travis puts it plainly: Hill Country ground varies parcel to parcel.
If you already own the land, the geotechnical engineer is engaged early on our projects, before design begins. Who orders and pays for the report is a contract point, so settle it before the borings are scheduled. How long it takes varies by lot and lab schedule, so ask for the date the borings go in and the date the sealed report is due.
Frequently Asked Questions
What is a geotechnical report?
A geotechnical report is a written investigation of the soil and rock under a building site, prepared by a geotechnical engineer. It usually contains boring logs, lab results, a site description and foundation recommendations, and it carries the engineer’s seal.
Does Texas require a geotechnical report for a custom home?
The rules are conditional. The International Residential Code leaves the soil test to the building official, and the Texas Occupations Code ties engineered slab design to expansive soil as the IRC classifies it. We require one on our projects regardless.
How many borings does a lot need, and how deep?
The Texas Section of the American Society of Civil Engineers recommends borings at least 20 feet deep unless confirmed rock is found sooner, and says one boring may be enough for a simple residence under 2,500 square feet. It says more may be needed on sites with fill, large footprints, steep slopes or nearby fault zones. Those are recommended-practice figures, and the geotechnical engineer sets the plan for your lot.
What are the plasticity index and potential vertical rise?
The plasticity index measures the range of moisture over which a soil stays plastic, and the International Residential Code counts a PI of 15 or greater as one of its criteria for expansive soil. Potential vertical rise is the engineer’s estimate, in inches, of how far the soil could swell under stated conditions. Both help the engineer choose and size the foundation.
Can I get a geotechnical report before I buy the lot?
Yes, if the contract allows time and access for borings. Where the sale uses TREC’s Unimproved Property Contract, the buyer can negotiate an option period for an option fee, and the seller must allow access at reasonable times. The form does not mention soil reports, so ask your agent to build in enough days and express permission to drill.
Who orders and pays for the geotechnical report, and how long does it take?
Who orders and pays for it is a contract point, so settle it before the borings are scheduled. On our projects the geotechnical engineer is engaged early, before design begins. Timing varies by lot and by lab schedule, so ask for the date the sealed report is due.
Every home we build starts with what is under the lot. We read the geotechnical report before design starts, so the house is drawn for the land you own. If you have land on Lake Austin, in West Lake Hills, central Austin or the Hill Country, or you are weighing a lot before you close, and want the report read by the team that will design and build on it, call (512) 402-9222 or start a conversation with our team.
Planning a custom home?
Our architects and builders work as one team, from the first conversation to the day you move in.